Technical Data

DimensionsMediumLarge
Overall dimensions42cm x 57cm x 9cm52cm x 77cm x 9cm
Mounting dimensions38cm x 53cm ±1cm48cm x 73cm ±1cm
Inner width20cm x 30cm30cm x 50cm
Component thicknesses
 Standard2cm - 10cm
 with optional Spacer ≤ 2cm
 with optional Tunnel10cm - 75cm
Thermal insulationEconomyPassive House
thermal transmittance0,811 W/(m²K)0,523 W/(m²K)
Air tightness according EN 12207 - 1999–11
Class 4
Driving rain resistance according to EN 12208 - 1999–11
ClassE1050
RFID (Animal ID)
Implanted or external Transponders per ISO standards 11784 / 11785 FDX-B
Range with implanted transponders0-15cm
Range with collar tag transponders15-30cm
Burglary resistance
Through a contactless access control system Through a built-in alarm system
Through a contactless access control system By integrating into existing alarm systems
Through a contactless access control system By using WK2 certified hardware and high-strength materials
Climatic conditions
Inside0°C to +40°C
Outside-40°C to + 85°C
Power supply
Input voltage90-264V AC
Output voltage24V DC
Base load0,2A
Cable length1,8m
Accu Pack12V 0,8A
Clock backup batteryCR3220
Sensors
Capacitive movement sensors
PIR movement sensors
Light sensor
Rain sensor (optional)
IR-Receiver
Reed contact
Secondary Reed contact (optional for door assably)
Interfaces
Output for external alarm systems
Serial interface